Introduction
9HGlnymlx3E
before you begin the installation view this entire video to familiarize yourself with the process installation of a Sub Zero unit should only be done by a qualified installer to ensure the safe and efficient installation of Sub Zero equipment please watch for the following types of highlighted information caution signals a situation where minor injury or product damage may occur if instructions are not followed warning states a hazard that may cause serious injury or death if precautions
2019-01-09T00:00:00.000Z
PT0M35S
false
false
false
Site Preparation
BYOJUOeOZsA
measure the intended rough opening space according to the specifications in the installation or design guide the depth of all integrated models is shown before panels are installed the standard rough opening depth is shown however you may need to adjust this based on the thickness of your panels in order to be flush with surrounding cabinets for tall models custom panels can exceed the height of the unit as long as their weight is below the recommended limit adjust the height of the rough opening according to the height of the panels if the door panel is taller than the unit a decorative valance may be used to finish the area behind the door panel the valance must stay behind the front plane of the finished moulding finish the inside edges of the rough opening along with the sides and a portion of the backside of decorative panels they will be exposed when the doors are open as the reveal between the cabinets and the integrated unit decreases the potential for severe finger pinching increases toe-kick clearance varies with the height of the lower drawer panel or the overall column panel height integrated models can accommodate various toe-kick heights a clearance below the bottom of the drawer or column panel must be kept so the unit is properly vented any decorative base molding must be removable for servicing and condenser cleaning and cannot cover the kickplate louvers two integrated units may be placed side by side in a dual installation see the Sub Zero design guide for the required dimensions for your units a dual installation kit is required for installations with two inches or less between the units kits are available through your sub-zero dealer if a 27 inch unit is installed next to a 36 inch unit the decorative front panels will align however the face frames will not this is only visible when both doors are open doors must be able to open to 90 degrees also be sure to leave enough clearance
2019-01-09T00:00:00.000Z
PT2M15S
false
false
false
Electrical Requirements
vkviXplRpsg
this is Section four this appliance requires its own circuit breaker and electrical supply all sub-zero models come with a power cord and three prong plug which must be plugged into a three prong grounding type wall receptacle follow the National Electrical Code and local code ordinances when installing the receptacle warning do not use an extension cord or two prong adapter do not remove the power supply cord ground prong electrical ground is required on this appliance the electrical outlet must be placed so that the grounding prong is to the right of the thinner blades the outlet must be flush with the back wall a ground fault circuit interrupter is not recommended and may cause interruption of operation a qualified electrician must check the outlet to be sure that it is wired with the correct polarity provides the appropriate power supply and is properly grounded Electrical location requirements are shown for 27 inch and 36 inch wide models the outlet must be placed within the shaded area in order for the unit to
2019-01-09T00:00:00.000Z
PT1M15S
false
false
false
Plumbing Requirements
cK7b45VJHVg
four integrated models with an automatic icemaker rough-in the water supply line be sure there is an accessible shutoff valve between the water supply and the unit do not place the shut-off valve behind the unit do not use self piercing valves a saddle valve package is available from your sub-zero dealer this indicates the placement of the water line when routing through a side wall place the line as close to the floor and back wall as possible the line must be routed so it clears the anti-tip bracket and the leveling feet of the unit keep excess water line outside the wall or floor for easy connection to the unit a line filter is required when water conditions have a high sediment content the ice maker requires consistent water pressure in the range shown a reverse osmosis system can be used provided this water pressure is supplied to the water valve at all times do not route the water supply line in front of the compressor tray the tray must be slid forward for service it is recommended the water line be taped to the floor so that it stays in place when the unit is moved into position
2019-01-09T00:00:00.000Z
PT1M19S
false
false
false
Anti-Tip Bracket Installation
31jfk1NEIf0
warning to prevent the unit from tipping forward it must be secured with the anti tip bracket shipped with the unit before installing the bracket protect your eyes with safety glasses especially when drilling into either wood or concrete warning the unit could tip forward under certain load conditions failure to install the anti tip bracket and extend the Levellers to the floor could result the bracket must be installed on a solid base there must be 24 inches from the front of the unit without panels to the back of the anti tip bracket if you are installing in a space deeper than 24 inches position the bracket so it engages the unit properly position the bracket as shown warning make sure that there are no electrical wires or plumbing in the area which the screws could penetrate use the screws and washers provided drill pilot holes then be sure the screws penetrate through the flooring material and into the wall plate be sure that the screws hold tight for concrete floor applications use the concrete wedge anchors screws and washers provided use a carbide drill bit manufactured within an cb90 for 1277 drill pilot holes then be sure the screws penetrate into the wall plate be sure that the screws hold tight use the carbide drill bit and drill a hole that exceeds the minimum embedment clean the hole assembled the washer and nut flush with the end of the anchor to protect threads drive the anchor through the material to be fastened until the washer is flush with the surface material repeat with the second anchor tighten the nut three to five turns past hand tight or 225 foot-pounds of torque anchors are not recommended for use in lightweight materials such as block or brick or for use in new concrete which
2019-01-09T00:00:00.000Z
PT2M14S
false
false
false
Postition the Unit
XtGwX17RRsA
if a dual installation is being used please refer to the dual installation section before positioning the units before moving the unit into the home verify the finished flooring is properly and set aside the kickplate trim molding before moving the integrated unit into position secure the door closed and remove drawers when applicable for drawer units disconnect the control cable in the top drawer before removing drawers when moving the unit position and appliance dolly at the side to prevent damage to finished surfaces if the unit has been laid on its back or side you must allow it to stand upright for a minimum of 24 hours before connecting the power plug the power cord into a live 15 amp grounded electrical outlet press the power key pad on the control panel check lighting and cooling once you see that the unit is operating properly shut off power to the outlet at the circuit breaker screw the front leveling legs out slightly for columns and tall models attach the top molding strip with the velcro fasteners if necessary install the decorative valance in the rough opening protect the signs of the opening by covering the outside of the mounting clips carefully slide the unit into position verify the anti-tip bracket is engaged properly when the unit is installed the anti-tip bracket will be positioned just above the engaging bracket it is not necessary to raise the unit to lock into the anti tip bracket but it must be in alignment with it the floor under the unit must be at the same level as the surrounding finished floor to allow the compressor tray to be slid forward for service warning to reduce the possibility of the unit tipping forward the front leveling legs must be in contact with the floor to raise the unit use a screwdriver to turn the front leveling legs clockwise turn counterclockwise to lower it to adjust the rear leveling legs turn the phillips head screw located in the front of the base the rear leveling legs will only move 1/16 of an inch for every 18 revolutions on the screw use the lowest torque setting on any power screwdriver do not over torque do not turn the rear leveling legs by hand once the unit is
2019-01-09T00:00:00.000Z
PT2M47S
false
false
false
Molding, Water Line, Kickplate Installation
bbb6g9pJubA
snap the side molding strips into place over the clips attached to the side of the unit for side by side installations refer to the dual installation section warning shut power off at the circuit breaker before making the water line connection purge the water line prior to final connection to the unit for units with an ice maker locate the quick-connect water valve and PEX tubing on the bottom right hand side of the unit to connect the icemaker water line attach the Union fitting to the copper house water supply line pull the PEX tubing toward the supply line remove the red cap then attach the tubing to the union with the nut tighten all connections recoil the excess tubing under the unit turn on the water supply and check for leaks in areas with water of high mineral content an inline water filter is recommended make sure the filter is accessible for replacement when necessary the first few batches of ice produced should be discarded allow 24 hours for proper ice production install the kick plate with the screws provided in order to fit flush some adjustment to the kick plate mounting assembly may be required the kick plate must be removable for servicing the floor cannot interfere with removal the kick plate allows for ventilation you may cover the solid area but do not block the louvers the panel may hang in front of the louvers but baseboard molding must not cover them turn power back on to the electrical outlet
2019-01-09T00:00:00.000Z
PT1M39S
false
false
false
Panel Installation
UxfuE7yoIMo
the integrated design accepts custom wood or other decorative panels and handles make sure that the panel's you are about to install match the dimensions and weight restrictions listed in the installation and design guides D style handles are recommended screw heads may have to be countersunk to not interfere with the panel fitting flush with the door or drawer install the door panel of tall units first then the upper and lower drawer panels place the door panel facedown on a protected surface and position the plastic template use caution when drilling bracket holes especially with inset panels to prevent damaging the panel the template for tall units has two sides make sure to use the proper side and holes locate the bracket then remove the template and carefully drill pilot holes place the bottom holes of the bracket over the pre-drilled holes and secure after the bracket has been secured to the pilot holes drill the remaining bracket holes and secure the bracket to the panel places screw in the center of the upper and lower mounting position just enough that the slotted holes of the hinge side door panel bracket will slide under the heads these screws will support the panel during installation engage the handle side bracket first then slide the hinge side mounting bracket onto the screws the panel can be adjusted one quarter of an inch up and down and side-to-side once the panel is in place and adjusted attach the remaining screws to the mounting bracket then install the magnetic decorative caps bracket position is based on 1/8 inch to 1 the smaller the reveal between cabinets the greater the risk of severe pinching when fingers are placed near the opening while the doors close place drawer panels facedown on a protected surface and position the plastic template the bottom drawer allows for two mounting bracket positions depending on the height and thickness of the panel locate the bracket position mark the holes then remove the template and carefully drill pilot holes position the mounting brackets with the tab bracket on top and L bracket on the bottom of the panel and secure them examine the lower L bracket and panel to determine the slotted holes on the bracket that will be used position screws into the lower portion of the drawer that corresponds with these slots leave the screws out slightly so the slotted holes will slide under the heads install the panel by engaging the top bracket first then slide the lower L bracket onto the positioning screws each panel can be adjusted one quarter inch side to side and up and down tighten screws but leave room for adjustment place drawers back in the unit for drawer units reconnect the control cable for the top drawer make any necessary adjustments then
2019-01-09T00:00:00.000Z
PT3M01S
false
false
false
90-Degree Door Stop
PiN1xeWbn9k
a 90-degree doorstop is built into the hinge system of all column and tall units use a standard screwdriver blade to rotate the cam until you reach the stop make this adjustment to both the top and
2019-01-09T00:00:00.000Z
PT0M14S
false
false
false
Dual Installation
Tl44cazV83I
this section covers information specific to installing two integrated units side by side be sure to also review the position the units section of this video for detailed instructions on properly positioning your units a dual installation kit is required when two or more integrated units are placed less than two inches apart kits are available from your sub-zero dealer there is one for two tall units one for a column unit next to a tall or column unit and one for a drawer unit next to any remove foil from the mounting holes place the heater assembly against the left side of the right hand unit using the heater as a template mark mounting holes the mounting holes only drill through the outer shell do not allow the drill bit to penetrate the inner liner attach the heater assembly to the cabinet loosen the two screws holding the left kick plate bracket and pull the bracket forward pass heater wires through the slot behind the bracket then press the hakko bushing into the keyhole slot to insert the four prong male connector into the female connector then insert wires into the male connector matching wire colors black to gray or purple black to white and green to green units are now ready to be installed side by side if they are more than 1/4 inch apart Center molding and brackets cannot remove clips from adjoining sides of each unit and tape over the screw holes install and level both units using the two hole steel brackets secure the units attach the top molding strips if a 27 inch tall unit is being installed next to a 36 inch tall unit the Z shaped bracket must be used at the insert the Center molding strip between the units secure the units in place attach the side molding strips reinstall remove clips from adjoining sides of each unit and tape over the screw holes attached refrigerator to counter brackets at adjoining top front corners install and level both units using the two hole steel brackets secure units at the base secure to underside of countertop insert the Center molding strip between the units secure the units in place attach the side molding strips remove clips from the adjoining side of the drawer unit then remove only the two lower clips from the adjoining side of the tall unit tape over the screw holes attache refrigerator to countertop brackets to the top front corner of the drawer unit attach the top moulding strip install and level both units secure the units at the base using the two hole steel brackets secure the drawer unit to the countertop insert the Center molding strip between the units secure the units in place attach the side molding strips necessary cut the adjoining side molding strip on the tall unit with a hacksaw
2019-01-09T00:00:00.000Z
PT3M50S
false
false
false
Installation Checklist
-L8JtTSKFvk
now that you have finished the installation of an integrated unit you will want to go through the installation checklist has the anti-tip bracket been installed properly is it making contact with the unit is the unit level are all leveling legs making contact with the floor is the power cord plugged into a properly grounded three-prong outlet which has been installed in accordance with all applicable electrical codes is the water supply connected for units with an automatic ice maker have you checked for leaks has the kick plate been installed properly are panels attached securely and properly aligned has the door been aligned for proper appearance and operation does the customer understand the unit's operation have you given the customer the warranty package have any installation or service problems been noted on the product registration card has the registration card been mailed in have stainless steel panels been inspected for any imperfections this is to be done by the dealer or installer with the customer classic stainless steel panels are covered by a limited 60-day parts and labor warranty for cosmetic defects any questions or problems about this installation should be directed to your subzero dealer or the sub-zero customer service department at 800-222-7820 warning if you are storing or disposing of your old refrigerator or freezer please do it safely remove the doors or tightly secure the doors closed
2019-01-09T00:00:00.000Z
PT1M37S
false
false