600 Series Refrigerator or Freezer Lights Not Turning Off
Topics:
- 600 Series refrigerator or freezer lights not turning off
- 600 Series lights stay on all the time
- Switch depressor missing
- Defective light switch
Steps to Verify Issue:
600 Series models (except 601R and 601F):
- If applicable, verify the accent lights are not the issue.
- Ensure nothing is preventing the door from fully closing.
- Open the door and verify the switch depressor located at the top center of the door. If missing, replace the switch depressor.
- Push the light switch (switch on left-hand side) in and out and wiggle it back and forth. If the lights are not affected, replace light switch. See Light Switch Instructions.
601R and 601F models:
- If applicable, verify the accent lights are not the issue.
- Ensure nothing is keeping the door from fully closing.
- Open the door and push the light switch (switch on right-hand side) in and out and wiggle it back and forth. If the lights are not affected, replace the light switch. See 501 and 601 Models and 501 & 601 Series Grille Removal.
Answer:
Replace the light switch.
- 600 Series (except 601R and 601F) light switch part number: 7014646
- Models 601R and 601F light switch part number: 7004257
Verify availability and part number accuracy using the Parts Price List. Contact a Factory Certified Parts Distributor to order parts.
If these steps do not resolve the issue, no further troubleshooting advice is available. Contact Factory Certified Service to schedule an appointment for repair.
See also, 600 and 700 Series Door Ajar Alarm.
DID THIS ANSWER YOUR QUESTION?
Thank you for your feedback!
Thank you for your request. A Customer Care representative will contact you.
We are sorry we weren’t able to answer your question. Please see these related answers.
If you need further assistance, contact Customer Care at 800-222-7820 or [email protected]
An error occurred. We were unable to submit your request.
Related Questions
-
Sub-Zero Classic Series Load / Component Faults | Refrigerator | Unstable | Error 60 1 02
-
MDD Drop-Down Door Microwave Touch Pad or Control Not Working
-
Classic (BI) Series Relay Faults | Water Systems | Water Check Valve Closed | Error 15 U 11
-
Classic Series Relay Faults | Water Systems | Water Check Valve Open | Error 15 U 10
-
Sub-Zero Classic Series Load / Component Faults | Freezer | FET Power Output Fault | Error 60 2 38
-
Sub-Zero Classic Series Load / Component Faults | Freezer | Unstable | Error 60 2 02
-
Sub-Zero Classic Series Ice / Water / Accessory Faults | Dispenser | Closed | Error 30 9 01
We're standing by with answers
Whether you're shopping for appliances or have questions about those you already own, we've got the resources you need. Talk directly to a customer care expert at the Sub-Zero, Wolf, and Cove service center, or connect with an appliance consultant at an official showroom near you. Get quick answers online, or reach a certified service provider or installer. And much more.
Call us at (800) 222-7820